INSTRUCTIONS FOR MEDICINAL USE OF THE MEDICINAL PRODUCT IMUNATE (IMMUNATE)

Composition:

Active substances: human blood coagulation factor VIII, von Willebrand factor (vWF:RCo);

1 vial of powder contains:

Active substance

Content of substance per vial

250/190 IU

500/375 IU

1000/750 IU

Blood coagulation factor VIII (corrected for albumin content)*

250 IU

(50 IU/mL)

500 IU

(100 IU/mL)

1,000 IU

(100 IU/mL)

Specific activity**

(70 ± 30) IU/mg protein

von Willebrand factor (vWF:RCo)***

190 IU

(38 IU/mL)

375 IU

(75 IU/mL)

750 IU

(75 IU/mL)

solvent: water for injections – 5 ml (for 250/190 IU and 500/375 IU) and 10 ml (for 1000/750 IU);

Excipients: human albumin, glycine, lysine hydrochloride, sodium chloride, trisodium citrate dihydrate, calcium chloride dihydrate.

____________________________________________________________________

* Factor VIII activity was determined using the WHO international standard for factor VIII concentrates.

** Without stabilizer (albumin).

Maximum specific activity at a factor VIII to von Willebrand factor antigen ratio of 1:1 is 100 IU per mg of protein.

*** von Willebrand factor activity was determined using the WHO international standard for factor VIII and von Willebrand factor concentrates in plasma.

Pharmaceutical form. Powder and solvent for solution for injection.

Main physicochemical properties: powder or brittle white or pale yellow substance.

Pharmacotherapeutic group. Haemostatics. Coagulation factors. von Willebrand factor in combination with coagulation factor VIII.

ATC code B02B D06.

Immunological and biological properties.

Pharmacodynamics.

The factor VIII/von Willebrand factor complex consists of two molecules (blood coagulation factor VIII and von Willebrand factor) which have different physiological functions.

Activated factor VIII acts as a cofactor for activated factor IX, accelerating the conversion of factor X to activated factor X. Activated factor X converts prothrombin into thrombin. Thrombin then converts fibrinogen into fibrin, forming a fibrin clot. Hemophilia A is an X-linked inherited coagulation disorder due to reduced levels of factor VIII activity, causing severe bleeding into joints, muscles, and internal organs, occurring spontaneously or following accidental or surgical trauma. Plasma factor VIII levels are increased by replacement therapy, which temporarily corrects the factor deficiency and bleeding tendency.

Besides its role as a protective protein for factor VIII, von Willebrand factor (vWF) mediates platelet adhesion to sites of vascular injury and plays a role in platelet aggregation, being essential for replacement therapy in patients with von Willebrand disease.

Pharmacokinetics.

Pharmacokinetic parameters obtained from a pharmacokinetic study in patients aged over 12 years are presented in Tables 1 and 2.

Table 1 describes the pharmacokinetic properties with respect to coagulation factor VIII.

Parameter

Number of patients

Mean value

Standard deviation

Median

90% CI

AUC0–48 h ([MU × h]/mL)

18

11.4

2.8

11.6

10.9–12.7

AUC0–∞ h ([MU × h]/mL)

18

12.2

3.1

12.4

11.1–13.2

Cmax (MU/mL)

18

1.0

0.3

0.9

0.8–1.0

Tmax (h)

18

0.3

0.1

0.3

0.3–0.3

Terminal elimination half-life (h)

18

12.7

3.2

12.2

10.8–15.3

Clearance (mL/h)

18

283

146

232

199–254

Mean residence time (h)

18

15.3

3.6

15.3

12.1–17.2

Vss (mL)

18

4166

2021

3613

2815–4034

Recovery ratio of activity level ([MU/mL]/[MU/kg])

18

0.020

0.006

0.019

0.016–0.020

Table 1

Table 2 describes the pharmacokinetic properties according to the FV antigen.

Table 2

Parameter

Number of patients

Median

90% CI

AUC0–∞([MO × h]/mL)

15

24.6

12.8–48.3

Cmax (MO/mL)

17

1.40

1.15–1.51

Tmax (h)

17

0.28

0.25–1.00

Terminal elimination half-life (h)

16

13.6

10.5–47.2

Clearance (mL/h)

15

136

68–178

Mean residence time (h)

15

23.1

12.4–57.1

Vss (mL)

15

3156

2391–4672

Recovery ratio of activity level ([MO/mL]/[MO/kg])

17

0.028

0.024–0.030

Clinical characteristics.

Indications.

Treatment and prevention of bleeding in patients with hemophilia A (congenital factor VIII deficiency, hemophilia A with factor VIII inhibitor, acquired factor VIII deficiency due to spontaneous development of factor VIII inhibitors).

von Willebrand's disease with factor VIII deficiency.

Note. The efficacy and safety of the Imunat preparation in von Willebrand–Jürgens syndrome have been clinically studied only in a small number of patients. This should especially be taken into account for type 3 of this disease.

Contraindications.

Hypersensitivity to the active substance or to any of the excipients of the medicinal product.

Interaction with other medicinal products and other forms of interaction.

Studies on interactions with the Imunat preparation have not been conducted. There have been no reports of specific interactions between human blood coagulation factor VIII and other medicinal products.

Special precautions for use

As with all intravenously administered substances, allergic-type hypersensitivity reactions may occur. Patients should be informed about early signs of hypersensitivity reactions, including hypotension, tachycardia, chest pain, dyspnea, swelling (particularly facial and eyelid edema), urticaria, rash, hyperemia, and pruritus, as well as anaphylaxis up to anaphylactic shock.

If symptoms of hypersensitivity occur, patients should be advised to immediately discontinue administration of the drug and contact their physician. In case of shock, standard medical treatment for shock should be administered.

Other infusion-related reactions have also been reported with Immunate, such as chills, fever, or nausea.

Since the sodium content in the maximum daily dose may exceed 200 mg, this should be taken into account by individuals on a low-sodium diet.

250 and 500 IU per vial

Immunate contains approximately 9.8 mg of sodium per vial. This corresponds to 0.5% of the 2 g maximum daily sodium intake recommended by WHO for adults.

1000 IU per vial

Immunate contains approximately 19.6 mg of sodium per vial. This corresponds to 1% of the 2 g maximum daily sodium intake recommended by WHO for adults.

The development of neutralizing antibodies (inhibitors) against factor VIII is a known complication during treatment of patients with hemophilia A. These inhibitors are usually IgG immunoglobulins directed against the anticoagulant activity of factor VIII, quantified in Bethesda Units (BU) per 1 mL of blood plasma using a modified assay. The risk of inhibitor development correlates with disease severity and exposure to factor VIII. The risk is highest during the first 50 days of treatment but persists throughout life, although it is rare.

Patients receiving treatment with factor VIII coagulation factor products should be closely monitored for the development of inhibitors through appropriate clinical observations and laboratory testing (see also section "Side effects").

The risk of inhibitor development depends on various factors related to individual patient characteristics. Key risk factors include, in particular, the type of factor VIII gene mutation, family history, and patient ethnicity.

Inhibitors have been predominantly reported in previously untreated patients.

Immunate is manufactured from human plasma. Standard measures to prevent infection from medicinal products derived from human blood or plasma include donor selection, screening of individual donations and plasma pools for specific infection markers, and effective manufacturing steps for virus inactivation/removal. Nevertheless, when using medicinal products derived from human blood or plasma, the possibility of transmitting infectious agents cannot be completely excluded. This also applies to unknown or emerging viruses and other pathogens.

The measures taken are considered effective against enveloped viruses such as human immunodeficiency virus (HIV), hepatitis B virus, hepatitis C virus, and also against the non-enveloped hepatitis A virus. However, the measures may have limited effectiveness against non-enveloped viruses such as parvovirus B19. Infection caused by parvovirus B19 may be dangerous for pregnant women (fetal infection) and for individuals with immunodeficiency or increased erythropoiesis (e.g., hemolytic anemia).

During long-term treatment of von Willebrand disease with a factor VIII-containing product, factor VIII:C levels may become excessively elevated. There is a risk of thrombotic events during treatment of patients with von Willebrand syndrome, especially in patients with known clinical or laboratory risk factors. Therefore, patients should be monitored for early signs of thrombosis. In patients with a history of venous thromboembolism, a high endogenous factor VIII level has been associated with an increased risk of subsequent thrombotic events.

In patients receiving a product containing von Willebrand factor and factor VIII, plasma levels of factor VIII:C should be monitored to avoid persistent excessive levels of factor VIII:C in plasma, which may increase the risk of thrombotic events.

Prophylaxis of venous thromboembolism should be performed according to current guidelines.

In patients with von Willebrand disease, especially those with type 3, neutralizing antibodies (inhibitors) against von Willebrand factor may develop.

Such antibodies may be closely associated with anaphylactic reactions. Therefore, patients experiencing anaphylactic reactions should be tested for the presence of such an inhibitor. If expected vWF:RCo plasma activity levels are not achieved or if bleeding is not controlled with an appropriate dose, testing for the presence of a von Willebrand factor inhibitor should be performed. In patients with high inhibitor levels, von Willebrand factor therapy may be ineffective, and alternative treatment options should be considered. Treatment should be administered under the supervision of a physician experienced in managing hemostasis disorders.

Patients who are regularly or repeatedly administered factor VIII derived from human plasma should be considered for appropriate vaccination (hepatitis A and B).

It is recommended that each time Immunate is used, the patient's diary should record the name and batch number of the product to establish a link between the patient and the product batch.

Immunate contains blood group isohemagglutinins (anti-A and anti-B). Hemolysis may occur in patients with blood group A, B, or AB after repeated administration at short intervals or after administration of very high doses. Very high doses over a short period may likely be used within immune tolerance induction therapy for treating hemophilia with factor VIII inhibitors.

Before prescribing Immunate, it must be confirmed that the coagulation disorder is indeed due to factor VIII deficiency (hemophilia A) or von Willebrand factor deficiency (von Willebrand syndrome).

Use during pregnancy and breastfeeding

Studies on the effects of factor VIII on reproductive functions in animals have not been conducted. Due to the rare occurrence of hemophilia A in women, there is no experience with the use of factor VIII during pregnancy and breastfeeding. Therefore, factor VIII should be used during pregnancy and breastfeeding only if clearly indicated.

For information on parvovirus B19 infection, see section "Special precautions for use".

Ability to affect reaction speed when driving or operating machinery

There is no information available on the effect of Immunate on the ability to drive or operate machinery.

Administration and dosage

Treatment should be administered under the supervision of a physician experienced in the treatment of hemophilia A.

Standard dosing

The dose and duration of replacement therapy depend on the severity of factor VIII deficiency, the location and extent of bleeding, as well as the patient's clinical condition.

The administered amount of factor VIII is expressed in International Units (IU), defined by the current WHO standard for factor VIII-based medicinal products. Factor VIII activity in blood plasma is expressed either as a percentage (relative to the normal human plasma value) or in International Units (relative to the international standard for factor VIII in plasma).

One International Unit (IU) of factor VIII activity is equivalent to the amount of factor VIII present in 1 ml of normal human plasma.

Dosing in hemophilia A

The required dose of factor VIII can be calculated based on the empirically established relationship: 1 International Unit (IU) of factor VIII per 1 kg of body weight increases factor VIII activity in plasma by approximately 1.5–2% of normal activity. The required dose can be determined using the following formula:

Required number of units (IU) = body weight (kg) × desired increase in

factor VIII activity (%) × 0.5

The dose amount and frequency of administration should always be adjusted to ensure clinical efficacy in each individual patient.

Bleeding episodes and surgery

In the event of ongoing bleeding episodes, factor VIII activity should not fall below the target plasma level (expressed as % of normal or IU/dL) during the appropriate period. The table below (Table 3) can be used to determine dosing during bleeding episodes and surgical procedures.

Table 3

Severity of bleeding/surgical procedure

Required Factor VIII level

(% of normal) (IU/dL)

Dosing frequency (hours)/duration of treatment (days)

Bleeding

Early hemarthrosis, muscle or oral cavity hemorrhage

20–40

Repeat every 12–24 hours for at least 1 day until cessation of bleeding, as indicated by absence of pain and wound healing.

More pronounced hemarthrosis, muscle hemorrhage or hematoma

30–60

Repeat infusion every 12–24 hours for 3–4 days or longer until pain resolves and significant functional impairment is eliminated.

Life-threatening bleeding

60–100

Repeat infusion every 8–24 hours until the threat is resolved.

Surgical procedure

Minor surgical procedure,

including tooth extraction

30–60

Every 24 hours for at least 1 day until wound healing.

Major surgical procedure

80–100

(before and after surgery)

Repeat infusion every 8–24 hours until adequate wound healing; thereafter, treatment should continue for at least another 7 days to maintain Factor VIII activity levels at 30–60% (IU/dL).

The dose and frequency of administration should be adjusted according to the clinical response in each individual case. Under certain circumstances (e.g., presence of a low titer of factor VIII inhibitor), especially at the beginning of treatment, doses higher than those calculated by the formula may be required.

If bleeding cannot be controlled with the calculated dose, plasma factor VIII levels should be determined and an adequate dose of Immunate administered to achieve a satisfactory clinical response.

During treatment, factor VIII activity should be monitored to determine the need for dose adjustment and frequency of repeated infusions. In the case of major surgical interventions, precise monitoring during replacement therapy by quantitative assay of factor VIII activity in plasma is essential. The response to factor VIII may vary among individual patients, with different half-life values and different degrees of in vivo recovery.

Long-term prophylaxis

For long-term prevention of bleeding in patients with severe hemophilia A, usual doses are 20–40 IU of factor VIII per kg body weight, administered every 2–3 days. In some cases, especially in young patients, shorter intervals between doses or higher doses may be required.

Patients with factor VIII inhibitors

Patients should be regularly monitored for the development of factor VIII inhibitors. If expected plasma factor VIII activity levels are not achieved or if bleeding is not controlled with an appropriate dose, testing for factor VIII inhibitor should be performed. In patients with high inhibitor levels, factor VIII therapy may be ineffective, and alternative treatment options should be considered. Management of such patients should be conducted under the supervision of physicians experienced in treating hemophilia, particularly in cases of factor VIII inhibitor development (see also section "Special instructions").

Cardiovascular events

Replacement therapy with factor VIII may increase cardiovascular risk in patients with existing cardiovascular risk factors.

Von Willebrand disease with factor VIII deficiency

Immunate is indicated for the treatment and prevention of factor VIII deficiency in patients with von Willebrand disease with factor VIII deficiency, and in cases where treatment with desmopressin alone is ineffective or contraindicated. Replacement therapy with Immunate for control of bleeding and for perioperative prophylaxis of bleeding should be carried out according to the same recommendations as for hemophilia A.

Experience with use in children is limited.

Patients should be monitored for the development of von Willebrand factor inhibitors if expected plasma von Willebrand factor activity levels are not achieved or if bleeding is not controlled with an appropriate dose. In patients with high inhibitor levels, von Willebrand factor therapy may be ineffective, and alternative therapeutic options should be considered (see also section "Special instructions").

When using a medicinal product containing both von Willebrand factor and factor VIII, the treating physician should be aware that continuous treatment may lead to excessive elevation of factor VIII:C levels. Consideration should be given to reducing the dose and/or prolonging the intervals between doses after 24 to 48 hours of treatment to avoid excessively high factor VIII:C levels.

Children

Immunate should be used with caution in children under 6 years of age who have had limited exposure to factor VIII products, as clinical data in this patient group are limited. However, based on case reports, efficacy and safety can be concluded.

Method of administration

Instructions for reconstitution of the medicinal product prior to administration are provided in the section "Dosage and administration".

Immunate should be administered slowly intravenously. The maximum infusion rate should not exceed 2 mL per minute.

Preparation of solution

Immunate should be reconstituted immediately before administration. The solution should be used immediately, as the product contains no preservatives.

Before administration, reconstituted medicinal products should be visually inspected for the presence of particulate matter and discoloration. Reconstituted solutions that are cloudy or contain particulate matter should not be used.

It is recommended to flush implanted venous access devices with isotonic saline solution before and after infusion of Immunate.

Reconstitution of powder: use aseptic technique as described below

  1. Warm the unopened vial of diluent (sterile water for injection) to room temperature (not exceeding 37 °C).
  2. Remove the protective caps from the powder vial and the diluent vial (Fig. A) and clean the rubber stoppers of both vials.
  3. Place the flanged end of the transfer device onto the diluent vial and press down (Fig. B).
  4. Remove the protective cover from the other end of the transfer set, taking care not to touch the open end.
  5. Invert the transfer set with the attached diluent vial over the powder vial and insert the free end of the needle into the rubber stopper of the powder vial (Fig. C). The diluent will be drawn into the powder vial by vacuum.
  6. Approximately one minute later, disconnect the two vials by removing the transfer set with the attached diluent vial from the powder vial (Fig. D). Since the product dissolves easily, gently swirl the concentrate vial slightly, if necessary. DO NOT SHAKE THE POWDER VIAL. DO NOT INVERT THE POWDER VIAL UNTIL READY TO WITHDRAW THE CONTENTS.
  7. After reconstitution, the prepared solution should be visually inspected for particulate matter and discoloration prior to administration. However, even with careful adherence to the reconstitution procedure, a few fine particles may occasionally be observed. These particles will be removed by the filter provided in the kit, without reducing the efficacy of the product.

Use aseptic technique as described below

  1. To prevent the introduction of rubber particles from the stopper (risk of microembolism), use the filter set provided in the kit. Attach the filter set to the disposable syringe provided and insert it through the rubber stopper (Fig. E).
  2. Disconnect the syringe from the filter set momentarily. Air will enter the powder vial, and any foam will dissipate. Then draw the solution into the syringe through the filter set (Fig. F).
  3. Disconnect the syringe from the filter set and slowly administer the solution intravenously (maximum infusion rate: 2 mL per minute) using the winged infusion set provided (or the disposable needle provided).

Any unused medicinal product or waste material should be disposed of in accordance with local requirements.

Solution preparation scheme: opening the ampoule, drawing up the solvent, mixing with the powder, aspirating the solution, loading into the syringe, injection

Children

Immunate should be used with caution in children under 6 years of age who have had limited exposure to factor VIII products, as clinical data in this patient group are limited. However, based on case reports, efficacy and safety can be concluded.

Overdose

No symptoms associated with overdose of human blood coagulation factor VIII have been reported.

The main risk is the development of thromboembolic events. In patients with blood group A, B, or AB, there is a risk of hemolysis (see also section "Special instructions").

Side effects

The adverse reactions listed below were identified during clinical trials and reported in the post-marketing period after marketing authorization for the medicinal product Imunat. The frequency categories are defined as follows: very common (≥ 10%); common (≥ 1% to < 10%); uncommon (≥ 0.1% to < 1%); rare (≥ 0.01% to < 0.1%); very rare (< 0.01%).

Clinical trials

The frequency of all adverse reactions listed below, as reported in clinical trials, was uncommon (≥ 0.1% to < 1%).

Immune system disorders

Uncommon: allergic reactions.

Spontaneous reports after marketing authorization

The frequency of all adverse reactions listed below was very rare (< 0.01%).

Blood and lymphatic system disorders

Coagulopathy, factor VIII inhibition.

Psychiatric disorders

Anxiety.

Cardiac disorders

Palpitations, tachycardia.

Gastrointestinal disorders

Vomiting, nausea.

General disorders and administration site conditions

Chest pain, chest discomfort, oedema (including peripheral oedema and facial oedema), injection site irritation (including burning sensation), chills, pain, pyrexia.

Immune system disorders

Hypersensitivity.

Nervous system disorders

Headache, dizziness, paraesthesia.

Respiratory, thoracic and mediastinal disorders

Cough, dyspnoea.

Vascular disorders

Hypotension, hyperaemia, pallor.

Eye disorders

Conjunctivitis, eyelid oedema.

Skin and subcutaneous tissue disorders

Erythema, exanthema, neurodermitis, pruritus, rash, erythematous rash, generalized rash, urticaria, hyperhidrosis.

Musculoskeletal and connective tissue disorders

Myalgia.

The following adverse reactions have not yet been reported, but may occur during treatment with Imunat.

Blood and lymphatic system disorders

Haemolysis in patients with blood group A, B or AB.

General disorders and administration site conditions

Decreased therapeutic response.

Description of selected adverse effects

Hypersensitivity or allergic reactions (which may include angioneurotic oedema, burning and prickling sensation at the infusion site, chills, erythema, generalized urticaria, headache, rash, hypotension, lethargy, nausea, anxiety, tachycardia, chest tightness, prickling, vomiting, wheezing) have been observed rarely and in some cases may progress to severe anaphylaxis (including shock). Patients should be advised to seek medical attention if these symptoms occur.

Pyrexia has been observed in rare cases.

In patients with haemophilia A, neutralizing antibodies (inhibitors) to factor VIII may develop. If such inhibitors develop, the condition presents as inadequate clinical response. In such cases, referral to a specialized haemophilia treatment center is recommended.

Haemolysis may occur after administration of high doses (e.g., when it is necessary to achieve factor VIII levels in blood plasma above 100%) in patients with blood group A, B or AB.

For information on viral safety, see section "Special precautions for use".

Reporting of suspected adverse reactions

Reporting suspected adverse reactions after marketing authorization is important. It allows continued monitoring of the benefit-risk balance of the medicinal product. Healthcare professionals and patients, or their legal representatives, are encouraged to report any suspected adverse reactions and lack of efficacy via the automated pharmacovigilance information system at: https://aisf.dec.gov.ua.

Shelf life

Medicinal product: 2 years.

Solvent (water for injections): 5 years.

Storage conditions

Store at 2 to 8 °C. Do not freeze. Store in the original packaging to protect from light. Keep out of reach of children. Within the stated shelf life, the medicinal product may be stored at room temperature (not above 25 °C) for up to 6 months.

After reconstitution, the medicinal product may be stored at room temperature (not above 25 °C) for up to 6 hours.

Incompatibilities

Imunat must not be mixed with other medicinal products, as this may adversely affect safety and efficacy. Only the provided infusion sets should be used, as adsorption of human coagulation factor VIII to the internal surface of certain infusion devices may result in reduced treatment efficacy.

Packaging

One vial of powder (250/190 IU, 500/375 IU or 1000/750 IU) with one vial of solvent (water for injections, 5 ml or 10 ml), and one reconstitution and administration kit (one transfer device/filter, one single-use syringe (5 ml or 10 ml), one single-use needle, one infusion set) in a carton.

Prescription status

Prescription only.

Manufacturer

Takeda Manufacturing Austria AG, Austria.

Manufacturer's address and location of operations